# SAP/BSS computational subprograms FORTRAN II accepts repeatable `--bss module.cbn` options. The loader reads 160-byte column-binary cards with P7B record markers and odd parity, checks their BSS checksums, relocates address/decrement fields and resolves transfer vectors. Calls execute a bounded computational subset of the IBM 704. Build and try the independently authored ABI example: ```sh make python3 tools/sap.py tests/sap/double.sap -o /tmp/double.cbn python3 tools/sap.py tests/sap/bump.sap -o /tmp/bump.cbn python3 tools/sap.py tests/sap/hwords.sap -o /tmp/hwords.cbn python3 tools/sap.py tests/sap/common.sap -o /tmp/common.cbn ./fortran704 --bss /tmp/double.cbn --bss /tmp/bump.cbn \ --bss /tmp/hwords.cbn --bss /tmp/common.cbn tests/sap/abi.f ``` This probe checks a real argument, fixed integer, COMMON, an array/EQUIVALENCE alias, a multiword Hollerith literal and its terminator, and a function return. Its printed values match original FORTRAN II objects loaded by the original BSS loader on both Sim704 and native i704. The separate `compiled.f` fixture also supplies a subroutine compiled by the original compiler; the local runtime executes that original object. The checked-in object contains only our own subroutine, with no IBM runtime or loader. ## Memory and calls There is one 32K physical word store. Code grows upward from address 128; FORTRAN data grows downward. COMMON starts at octal 77462, reserving the upper 205 historical system words. These are physical addresses, but local allocation does not reproduce every absolute address of original object code. The bottom 128 words are reserved for the host call bridge. Code/data collision, undefined reads and illegal stores through a live DO alias are diagnosed. An ordinary `CALL NAME(A,B)` supplies the first address of each argument in a synthetic calling sequence, with XR4 set as by TSX. Arrays descend from their first element; text literals ascend from their first character word. Hollerith storage persists at the call site, including mutations. Fixed integers use a sign and a 15-bit magnitude shifted 18 bits. Tape/drum transfers preserve raw words, including low bits not used by a fixed integer value. A routine with n arguments returns through `TRA n+1,4` and must restore all three index registers. A transfer into the reserved call area at any other address is diagnosed as an argument-count/return mismatch. Ordinary function names use I through N for fixed results and return the value in AC. For example `D=DOUBL(C)` calls the entry `DOUBL`. Terminal-F library-tape names use a different historical convention; loading replacements for those functions is unsupported. The six built-in library implementations remain available. A machine routine can call other linked machine routines; it cannot call back into an AST FORTRAN unit. Machine entry clears AC, MQ and machine indicators, sets XR1/XR2 to zero, and sets XR4 for the call. These are deterministic host-boundary values; arbitrary original compiler register context is not reproduced. Machine indicators are local to the call; MQ-overflow testing (TQO) is unsupported. At return, only S and magnitude bits 1 through 35 form the result word; Q/P are not part of a stored FORTRAN result. Execution is limited to one million instructions; unsupported instructions or floating inputs with Q/P bits set fail explicitly. No channels, trap mode, peripherals or machine timing are emulated by this bridge. It cannot boot a FORTRAN system or run an arbitrary original object main program. ## Assembler subset `tools/sap.py` requires Python 3.10+ and is an independent small assembler for bridge examples. Use whitespace-separated `label operation operand` or `operation operand` lines. An unlabelled operation must be a recognised mnemonic. Labels should avoid mnemonic names. Whole-line `*` comments and `REM` are supported; fixed-column SAP comments/macros are not. The first storage label is the default entry; repeat `--entry NAME` for up to ten explicit entry points (one to six letters or digits, beginning with a letter). Supported directives: `REL`, `ORG`, `EQU`, `SYN`, `BSS`, `BES`, `OCT`, `DEC`, `BCD`, `END`. `ABS` is rejected. Expressions allow decimal numbers, prior EQU/SYN definitions, labels, `*`/`.` for the location, addition and subtraction. EQU/SYN cannot refer forward. Explicit `NAME EQU -n` denotes upper memory; differences of lower-memory labels remain absolute. Relocation digit 11 is emitted when the numeric field falls on the other side of the program break, including a trailing BES label. Unsupported compound relocation is rejected. `OCT` supplies raw octal words. `DEC` supplies sign-magnitude integers, floating constants with 27 fraction bits, or `B`-scaled fixed constants. Its decimal conversion uses bounded decimal arithmetic and truncation; long-decimal equivalence to the historical SAP converter is not established. `BCD` uses a decimal word count immediately followed by text; use a non-digit first character (a blank can separate digit-leading text, and that blank is retained as data). All unfilled BSS/BES words are initialised to zero, a local assembler convention. Transfer-vector generation, automatic COMMON reservation, historical control cards, macros and the full original source syntax are outside this assembler. The supported machine operations are the explicit `OPCODES`, `PREFIX` and `SENSE` tables in `tools/sap.py`: common transfer/index, sign-magnitude and logical operations, normalised FAD/FSB/FMP/FDP/FDH, shifts, stores and tests. `PZE` and `MZE` are data words, not executable instructions. No unnormalised floating instructions, HTR/HPR, I/O or traps are implemented. Execution tests cover the bridge contract and selected instruction boundaries, not exhaustive hardware conformance. ## Loader limits and checks Program cards define up to ten entries and reserve a lower-memory extent. Relocation digits 0, 10 and 11 are supported in both fields. Upper-memory references and common-reassignment/control offsets can be relocated, but data cards must stay inside an allocated lower-memory module. Absolute data cards must also be inside the current module. Initialising upper COMMON through a BSS card is not supported. Runtime stores into associated COMMON are supported. Duplicate entries, unresolved transfer names, overlaps, truncation, bad parity and checksum failures are diagnosed. Original checksum suppression/zero-checksum conventions remain accepted. Run `python3 tests/test_sap.py` for the original-loader witnesses and local corruption, alias, relocation, register, instruction-limit and persistence checks. [Validation](word-machine-validation.md) records provenance and limits.